What was found
DURING DETAILED VISUAL INSPECTION OBSERVED CORROSION & CRACKS AROUND HOLES COMMON TO FAILSAFE STRAP & T FITTING. PREVIOUSLY MENTIONED ON NON-ROUTINE 1369. TRIMMED OUT CRACKED & CORRODED AREA OF FAILSAFE STRAP AS WRITTEN IAW EA 53500013-003 & DOCUMENT 47008ORD03. SDR INFO CRACKED 1/4", CORRODED LEVEL 2, PN 14372524, PART NAME, LEFT FAILSAFE STRAP, SN NSN, FS & BS LOCATION STATION 955. ACFT WAS GNDED.