What was found
REAR SPAR TO TE, UPPER PANEL ATTACH BEAM, UPPER CHORD CORRODED AROUND NUTPLATES AT WS 290 AS SEEN IN RT WW. FOUND ATTACH BEAM TO BE CORRODED OUT OF LIMITS IAW SRM 51-10-00. R & R ATTACH BEAM IAW SRM 51-40-2 & 51-40-5. CORRODED LEVEL 2, PN 113T1622-125, PART NAME CHORD, SN NSN, STRINGER & WS LOCATION WS 290. ACFT WAS GROUNDED.