What was found
DURING C-CHECK AT TAMPA MTX FOUND CORROSION COMMON TO STRINGER 33L AT STA.1576 ON BULK CARGO, COMPARTMENT INTERNAL SURFACE. THE STRINGER (P/N 146T3002-47) IS MADE FROM THE -267 WHICH IS M/F 0.140" THK 7075-0 BARE SHEET PER QQ-A-250/12, HT TO -T6. THE STRINGER THICKNESS AT THE DAMAGEL OCATION IS 0.100” PER BAC DWG 146T3002 SHT 3. THE DAMAGE IS REPAIRABLE PER B767-200 SRM 53-00-03,REPAIRED IAW SRM 53-00-03 REPAIR 2 DETAIL IV ., ABX REA-5300-65575-00.AND ABX-REA-5300-65575-01