What was found
DURING MAINTENANCE INSPECTION, "AFT DET FAN" EICAS MESSAGE. MAINTENANCE REPLACED AFT CARGO SMOKE DET AIR FLOW BLOWER 1, M718 PER B767 AMM 26-16-02. SYSTEM CHECKS NORMAL. AIRCRAFT RELEASED NO ETOPS. A/C RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE INSPECTION, "AFT DET FAN" EICAS MESSAGE. MAINTENANCE REPLACED AFT CARGO SMOKE DET AIR FLOW BLOWER 1, M718 PER B767 AMM 26-16-02. SYSTEM CHECKS NORMAL. AIRCRAFT RELEASED NO ETOPS. A/C RETURNED TO SERVICE.