As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK INDICATION FOUND DURING LFEC INSPECTION AT FASTENER COMMON WITH L/H SIDE STA 1809 BULKHEAD WEB BELOW UPPER LONGERON LOWER TENSION FITTING .REAMED 1EA HOLE TO .3407¿ PERFORMED OPEN HOLE HFEC AND DVI. NO CRACKS NOTED IAW NDT MANUEL PART 6 51-00-16, SRM 51-40-05 AND 51-10-02.