What was found
DURING C-CHECK INSPECTION WHILE COMPLYING WITH AD 94-03-01, FOUND LEVEL I CORROSION ON BOTH CROSSFEED CABLES AT STA 598, JUST BELOW LONGERON 19R. CLEANED CABLES IAW DC-9 SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION WHILE COMPLYING WITH AD 94-03-01, FOUND LEVEL I CORROSION ON BOTH CROSSFEED CABLES AT STA 598, JUST BELOW LONGERON 19R. CLEANED CABLES IAW DC-9 SRM 51-10-3.