What was found
EICAS MSG R ENG BLEED OFF DISPLAYED R ENG BLEED OFF LIGHT ILLUMINATED, CUICT PRESS NO RM 2119Z. REMOVED AND REPLACED FLOW CONTROL AND SHUTOFF VALVE PER AMM 21-51-01-2. RAN ENGINE, OPS CHECK NORMAL. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS MSG R ENG BLEED OFF DISPLAYED R ENG BLEED OFF LIGHT ILLUMINATED, CUICT PRESS NO RM 2119Z. REMOVED AND REPLACED FLOW CONTROL AND SHUTOFF VALVE PER AMM 21-51-01-2. RAN ENGINE, OPS CHECK NORMAL. (M)