What was found
PILOT REPORT: NOSE GEAR GREEN LIGHT FAILED TO ILLUM WITH GEAR HANDLE DN EICAS MSG NOT DISPLAYED. IAW AMM 32-09-03 PAGE 1414 WAS CHANGE THE NOSE GEAR GREEN LIGHT INDICATED RECEPTACLE FUNCTIONALLY LIGHT NORMAL IAW FIM 32-09-03 PAGE 106 FIG 103 BLOCKS 1, 2, 3, 4, 5, 6, 7 AND 8 THE PROXIMITY SWITCH ELECTRONIC (PSEU) BITE TEST PROCEDURE WAS PERFORMED, NO FAULT DETECTED, IN ADDITION IAW AMM THE 33-16-02 ANNUNCIATOR LIGHTS REPLACED BULBS WAS ACCOMPLISHED, CHECK AND TEST ON GROUND WAS SATISFACTORY.