What was found
DURING TAKE OFF, WHEN THRUST LEVERS WERE ADVANCED BETWEEN FLEX AND TOGA, ECAM WARNING SHOWED ENGINES THRUST LEVERS NOT SET, ENGINES DID NOT SPOOL UP RAPIDLY AS EXPECTED IN A NORMAL TAKEOFF, DECIDED TO ABORT TAKEOFF. GROUND RETURN WAS PERFORMED AND PERFORMED 2 ENGINES TEST THRUST WITH NO DISCREPANCIES OBSERVED. SUBSEQUEST TAKEOFF WAS DONE WITHOUT ANY ABNORMAL WARNINGS, NO ENGINES COND. PERFORMED TSM TASK 76-11-00-810-823A AND DID THE TEST IAW AMM: 76-11-19-400- 042 OPS CHECKED GOOD OF FOR SERVICE.