What was found
IAW TSM 73-00-00-810-866-A REV.62 REV-, THE FAULT ISOLATION PARAGRAPH 4 STEP A ITEM 2, A TO F WAS PERFORMED & SATISFACTORY . BOROSCOPE INSPECTION WAS ACCOMPLISHED NO RELEVANT DISCREPANCIES FOUND, NORMAL DETERIORATION, IAW TSM 73-10-00-810-836 AT THE STEP A.1.2.(A) CABLE J8 WAS CHECKED & RESISTANCE WERE IN LIMITS (19 OHMS) IAW AMM 73-21-60-00-001-B/400-001-B THE ECU WAS REPLACED ON NR 2 ENG, SATISFACTORY TEST. MINIMUM IDDLE CHECK 71-00-00-710-006-B PERFORMED, SATISFACTORY. IAW AMM 73-21-10-00-002-A, HMU REMOVED FROM RT ENG. IAW AMM 73-21-10-400-002-A HMU REPLACED. IAW AMM 73-29-00-710-040 OPS TEST OF FADEC PERFORMED & AMM 71-00-00-710-006 MINIMUN IDLE CHECK WAS PERFORMED , NO EVIDENCE OF LEAKS.