What was found
AFTER TAKE OFF & MLG WAS SELECTED UP ECAM INDICATION MLG NOT UPLOCKED IAW INSTRUCTIONS GIVEN ON THE JIC-32S-31-00069 REV. 03 THE PERSONAL COMPUTER MEMORY CARD (PCMCIA) DATA DOWNLOADING WAS PERFORMED IAW AMM 32-31-73-000-005-A/400-005-A THE NLG PROXIMITY-SENSORS (12GA713GA) WERE R & R IAW AMM 32-31-00-720-002-A FUNCTIONAL TEST OF NORMAL EXTENSION & RETACTION OF MLG WAS PERFORMED, TEST SATISFACTORY IAW AMM 31-33-55-000/400-002-A THE FDR FIN 1TU WAS REPLACED, AMM 23-71-35-000/400-001-A CVR FIN 1RK WAS REPLACED IAW AMM OPT 31-33-00-710-007-A DFDR WAS SUCCESSFULLY IAW AMM 23-71-00-710-001-A AND AMM 23-71-00-710-002-A OPT CVR RECORDING LOGIC SUCCESSFUL.