What was found
LOSS OF ALTIMETER 1 DURING TAKE OFF RUN BY FAULT MSG " LOSS OF THE FCU DATA INPUT BUS ON THE ADIRU1" IN ACCORDANCE WITH TSM: 34-13-00-810-921-A THE SYSTEM TEST OF THE ADR (SYS 1) WAS PERFORMED, TEST OK. BY TSM TASK: 34-13-00-810-921-A - ASM FIG: 34-13-02 SCH 02 - AWM FIG: 34-11-15 P0001 THE WIRING CHECK BY CONTINUITY OF THE DIGITAL BARO CORRECTION A BUS FROM ADIRU1(1FP1) PINS 15G AND 15F CONNECTOR A TO THE FIRST TERMINAL BLOCK 1851VT MODULE 41 PIN-P AND MODULE 42 PIN-U, WAS PERFORMED; THE WIRING CHECK WAS FOUND IN NORMAL CONDITIONS. IN ACCORDANCE WITH AMMTASK 34-13-00-790-002-A THE LEAK MEASURE TEST OF THE PRINCIPAL STATIC AND TOTAL AIR DATA SYSTEM WERE PERFORMED SATISFACTORY NO LEAKS FOUND IN ACCORDANCE WITH AMM 34-12-34-000-001A/400-001A ADIRU #1 WAS REPLACED TEST OPERATIONAL SATISFACTORY.