What was found
DURING FLIGHT AND ABOVE 16000 FT RIGHT SID TOILETS DIDNT WORK UPON INSPECTION OF THE CB PAGE CE38-32-804 WASTE SYS-R CB WAS FOUND TRIP AND LOUD BE RESET AFTER TWO ATTEMP TOILETS IAW AMM DMC-B787-A-38-32-61-02A-520A-A/720A-A THE VACUUM BLOWER, SIDE RH WAS REMOVED AND REPLACED. TEST SATISFACTORY PASSED. IAW AMM DMC-B787-A-24-71-05-00A-520A-A/720A-A THE POWER MODULE SLOT #3 OF THE RPDU 42 WAS REMOVED AND REPLACED.