SDR ARWA981101

Service difficulty report · Pump · Doug DC863F

Difficulty date
November 2, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N661AV
Make and model
Doug DC863F
Aircraft serial
45969
Part
Pump
Part number
57155A
Condition
Inop
Location
Aux Hyd Syst
Stage of operation
IN
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER LOADING WHILE CLOSING MAIN CARGO DOOR, AUXILIARY PUMP (HYD) BLEW CURRENT LIMITERS SEVERAL TIMES. REMOVED AND REPLACED AUX PUMP IAW DC-8 M/M 29-20-2. NO PRESS PRODUCED, SWAPPED REV PUMP AND AUX PUMP IAW DC-8 M/M 29-20-2, OPS CHECK GOOD.

More about the Doug DC-8-63F