What was found
PHX - DURING 15K CHECK, FOUND CORROSION ON L1 DOOR ENTRYWAY FLOOR SUPPORT BETWEEN STATION 160 AND 190, LBL 55. REMOVED CORROSION PER SRM 53-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING 15K CHECK, FOUND CORROSION ON L1 DOOR ENTRYWAY FLOOR SUPPORT BETWEEN STATION 160 AND 190, LBL 55. REMOVED CORROSION PER SRM 53-01. (M)