What was found
PHX - DURING 15K CHECK, FOUND TWO CRACKS WERE FOUND ON THE L2 SERVICE DOOR EXTERIOR SKIN AROUND THE DOOR HANDLE CUTOUT AT THE EXIT PLACARD. REPAIRED PER SRM 52-05, FIG 3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING 15K CHECK, FOUND TWO CRACKS WERE FOUND ON THE L2 SERVICE DOOR EXTERIOR SKIN AROUND THE DOOR HANDLE CUTOUT AT THE EXIT PLACARD. REPAIRED PER SRM 52-05, FIG 3. (M)