What was found
DURING C-CHECK, FOUND AFT CARGO BAY MAIN FLOORBEAM IS CORRODED. INSTALLED PERMANENT REPAIR IAW SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND AFT CARGO BAY MAIN FLOORBEAM IS CORRODED. INSTALLED PERMANENT REPAIR IAW SRM 51-30-2. (M)