What was found
GYR - MAIN DECK FLOORBEAM AT STATION 294.5 APPROX LBL 12 TO RBL 50, UPPER T-CAP HAS SEVERAL AREAS OF CORROSION ON UPPER SURFACE. BLENDED CORROSION CK OUT OF LIMITS. REMOVED 'T' AND REPAIR ANGLE EPR SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GYR - MAIN DECK FLOORBEAM AT STATION 294.5 APPROX LBL 12 TO RBL 50, UPPER T-CAP HAS SEVERAL AREAS OF CORROSION ON UPPER SURFACE. BLENDED CORROSION CK OUT OF LIMITS. REMOVED 'T' AND REPAIR ANGLE EPR SRM 53-10-51. (M)