What was found
FOUND FLOORBEAM AT BS 328 RBL 18 WEB CRACKED. REPAIRED FLOORBEAM WEB IAW SRM 51 40 02 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM AT BS 328 RBL 18 WEB CRACKED. REPAIRED FLOORBEAM WEB IAW SRM 51 40 02 FIG 1.