What was found
NR 3 SLAT T/E WEDGE DELAMINATED AT INBD AND OTBD ENDS. PREPPED DELAMINATED AREAS FABRICATED AND INSTALLED REPAIR CORE FILLER AND DOUBLER IAW SRM 51-70-10 REPAIR 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 SLAT T/E WEDGE DELAMINATED AT INBD AND OTBD ENDS. PREPPED DELAMINATED AREAS FABRICATED AND INSTALLED REPAIR CORE FILLER AND DOUBLER IAW SRM 51-70-10 REPAIR 4.