Service difficulty report · Controller · Boeing 737890

Difficulty date
March 2, 2008
Submitted
March 3, 2008
Operation
Air carrier
Aircraft
N559AS
Make and model
Boeing 737890
Aircraft serial
35178
Aircraft time
5,637 hours, 1,661 cycles
Part
Controller
Part number
8300005604
Condition
Faulty
Location
Window Heat
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB F/O'S SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. TURNED SWITCH OFF WAITED 5 MINS TURNED BACK ON. FIVE MINS LATER OVERHEAT LIGHT CAME BACK ON. RESET AGAIN LIGHT REMAINED OUT. NUMEROUS OP CHECKS GOOD. PER FIM 30 41 TASK 801 BITE PROCEDURE BIT VERIFY TEST OK. LAST 10 FLIGHTS SHOW "WINDOW SENSOR FAULT". PER FIM 30 41 TASK 811 RANG OUT RT SIDE WINDOW TEMP SENSORS. SENSORS CHECK GOOD. SHAKE DOWN OF SAME WINDOW COIL CORD GOOD. TEMP SENSOR WIRING TO WINDOW HEAT CNTL UNIT GOOD. PER FIM REPLACED WINDOW HEAT CNTL UNIT, OPS NORMAL.