As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER ENG START AND POSITIONING GEN SWITCHES ON THE AMBER "ELEC" LIGHT REMAINED ON IN THE OVERHEAD PANEL. "STAT INV INOP" SHOWS WITH BITE. FOUND "INVERTER REMOTE" CIRCUIT BREAKER OPEN. NO HISTORY. RESET CIRCUIT BREAKER. PERFORMED FIM 24 31 TASK 801 AND FIM 24 34 TASK 801. RESET FAULT REF SAME. OPS NORMAL STATIC INVERTER REF MM 24 34 21 400 801.