What was found
ONE HOUR AT CRUISE FLT ( FL360 & FL380) NR 1 TANK 730 LB BELOW NR 2 TANK. BOTH READ THE SAME AT TOP OFF CLIMB. NR 1 ENG FF 2.68 NR 2 FF 2.51. AT FL 380 X FEED TO BALANCE NORMAL GROUNDED YES. VERIFIED DISCREPANCY ON GROUND. REALIGNED CROSSFEED VALVE PER AMM 28 22 21 820 801. ACCOMP X FEED VALVE OPS TEST PER AMM 28 22 21 710 801. OPS CHECKED GOOD. ACCOMP X FEED VALVE FUNCTIONAL TEST PER AMM 28 22 00 730 802. NO FUEL TRANSFERRED. GROUND VERIFICATION SUCCESSFUL.