As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FIRE/OVHT TEST FAULTS ENG 2 A LOOP. VERIFIED ENG 2 A LOOP INOP. DUE HISTORY TECH SERV REQUESTS REPLACE FAN FRAME AND CORE A LOOP ENG HARNESSES. REPLACED ENG NR 2 FAN FIRE DETECT HARNESS REF MM 26 11 02 400 801. REPLACED ENG NR 2 CORE FIRE DETECT HARNESS REF MM 26 11 02 400 802. NR 2 ENG FIRE DETECT OPS TEST OPS NML REF MM 26 11 00 710 801.