What was found
NR 1 ENG BOTTOM RT EGT SIGNAL (T495S2) IS OUT OF RANGE. ACCOMPLISHED T49.5 PROBE AND EGT SYS INSPECTION IAW MM 77-21-01-200-801-F00. FOUND SLIGHTLY HIGH RESISTANCE BETWEEN PIN H AND PIN LOWER CASE A OF 15.6 OHMS ON CONNECTOR J9 DP0909. CLEANED CONNECTOR REF MM 70-70-01, SUBSEQUENT READING OF 5.95 OHMS AFTER CLEANING IS WITHIN LIMITS. ALL INSULATION RESISTANCE VALUES WITHIN LIMITS.