What was found
REF T/C SB737-22A1224-NG-1-1, LAND VERIFY TEST FAILS 49.32 (S051, ELEV POS SENSOR 1). BITE NR 32 STAB TRIM TEST INTERMITTENTLY FAILS ELEVATOR POSITION SENSOR ON CHANNEL A ONLY. ACCOMPLISHED STAB AND ELEVATOR RIGGING TEST REF MM 22-11-00, ALL VALUES ARE WITHIN LIMITS. ACCOMPLISHED PITCH FORCE TRANSDUCER TEST REF MM 22-11-92,TEST PASSED. ACCOMPLISHED CAPTS CONTROL COLUMN CUTOUT SWITCH TEST, TEST PASSED REF MM 27-41-00. FOUND FOS CONTROL COLUMN SWITCH OUT OF ADJUSTMENT. ADJUSTED SWITCH, REF MM 27-41-51. CONTROL COLUMN SWITCHES TEST NML, REF MM 27-41-00. ACCOMPLISHED DFCS LRU REPLACEMENT TEST FOR PITCH SENS, REF MM 22-11-30, DFCS LRU INTERFACE TEST FOR FCC, REF MM 22-11-33, LAND VERIFY TEST, REF MM 22-11-00, AND HGS SENSOR TEST FOR FCC/AT, REF SMM 34-36-00. ALL TESTS PASSED.