What was found
ON CLIMBOUT PASSING 26000 FT, RT SIDE WINDOW OVERHEAT LIGHT CAME ON. FOLLOWED QRH, RETURNED TO NORMAL OPS. REMOVED & REINSTALLED R2 WINDOW. SEALS GOOD. HISTORY SHOWS SENSOR FAULT. SENSOR OHMS GOOD & TERMINALS ARE TIGHT, REF MM 30-41-21. REPLACED R2 WINDSHIELD HEAT CONTROL UNIT AS A PRECAUTION. OPS CHECKED GOOD, REF MM 30-41-11. OPS CHECK R2 WINDOW HEAT GOOD. REF MM 30-41-00. ALSO REF FIM 30-41/T801.