What was found
AFTER START, & CHECKLIST PERFORMED. MASTER CAUTION AIR CONDITIONING LIGHT ILLUMINATED. RESET WITH MASTER CAUTION. CHECKLIST ACCOMPLISHED. PRIMARY OR SECONDARY TEMP CONTROL INOPERATIVE. RT PACK ZONE TEMP CONTROL BITE LOGS THIS PACK - TCV IN MEMORY. RESET FAULT, RE-RAN BITE, NO FAULTS NOTED. OPERATED RT PACK 15 MINUTES AND ACCOMPLISHED CABIN TEMP CONTROL AND INDICATION. OPS TEST IAW MM 21-61-00-700-807-002. OPS NORMAL. SUBSEQUENT BITE SHOWS NO FAULTS. NO PREVIOUS HISTORY.