What was found
AFTER TAKEOFF, LANDING GEAR WAS RETRACTED NORMALLY. DURING AFTER TAKEOFF FLOW, WHEN LANDING GEAR HANDLE WAS PLACED TO OFF, THE RED NOSE GEAR LIGHT ILLUMINATED AND WAS ACCOMPANIED BY NOSE GEAR AIR NOISE. FOLLOWED QRH AND RAISED HANDLE TO UP. PROCEEDED TO ANC IAW MC. LIGHTS WERE OUT. ACFT GROUNDED. PERFORMED GVI OF NOSE GEAR LOCK LINKS, BUNGEE SPRINGS, LOCK ACTUATOR, MAIN ACTUATOR, & VALVE MANIFOLD. NO DISCREPANCIES NOTED. JACKED ACFT AND SWUNG NOSE GEAR FIVE TIMES. NO FAULTS NOTED, NOSE GEAR CYCLED NORMALLY WITH PROPER INDICATION AND STAYED UP & LOCKED IN THE GEAR LEVER OFF POS. GROUND VERIFICATION SUCCESSFUL. REF MM 32-61-00-710-801.