What was found
E & E BAY FLOOR SUPPORT CRACKED AT FASTENER BS 312 - 328, LBL 46. ACFT GROUNDED. REMOVED CRACKED FLOOR SUPPORT. LOCATED AND DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-05 AND INSTALLED IAW SRM 51-40-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E & E BAY FLOOR SUPPORT CRACKED AT FASTENER BS 312 - 328, LBL 46. ACFT GROUNDED. REMOVED CRACKED FLOOR SUPPORT. LOCATED AND DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-05 AND INSTALLED IAW SRM 51-40-01.