Service difficulty report · Sensor · Boeing 737990ER

Difficulty date
December 20, 2013
Submitted
December 23, 2013
Operation
Air carrier
Aircraft
N409AS
Make and model
Boeing 737990ER
Aircraft serial
41733
Aircraft time
3,393 hours, 1,087 cycles
Part
Sensor
Part number
213A410113
Condition
Failed
Location
Temp Control
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL CABIN TEMP CONTROL INOPERATIVE. COCKPIT TEMP VERY COLD REGARDLESS OF WHERE CONTROL IS POSITIONED. ONLY WAY TO KEEP IT WARM IS TO TURN TRIM AIR OFF AND CONTROLL CAB OFF. ACFT GROUNDED. FOUND CONTROLL CABIN SENSOR FAULT ON BOTH PACK/ZONE TEMP CONTROLLERS. REPLACED CONTROL CABIN TEMP SENSOR. OPS CK GOOD. REF AMM 21-61-10.