What was found
RIGHT FMC FAILED, QRH PROCEDURE FOLLOWED WITH SINGLE FMC. ACFT GROUNDED. VERIFIED FAULT. CYCLED C/B FOR RT MFC & 10 MIN RT FMC BITE, INOPERATIVE WILL SHOW ON FMC CDU. REPLACED RT FMC WITH SERVICEABLE ONE. ACCOMPLISHED FMC SOFTWARE CROSSLOAD. AFTER CROSSLOAD VERIFIED SOFTWARE CONFIG. CHECK, CHECK SAME. ACCOMPLISHED FMC SYSTEM OPS TEST, TEST PASS REF, MM 34-61-02-400-801 & 34-61-00-470-806 & 34-61-00-710-801.