What was found
DURING LANDING, MASTER CAUTION LIGHT ILLUMINATED FOR A RT PACK, EXTINGUISHED WITH RESET. ACFT GROUNDED. IAW FIM 21-62, TASK 801, SHOWS INTERMITTENT RT RAM ACTUATOR FAULT. VERIFICATION TEST OK. FAULT RESET, RT PACK LIGHT REMAINS EXTINGUISHED ON RECALL.