What was found
OVERHEAT INDICATION CAME ON FOR R2 WINDOW. ACFT GROUNDED. CONFIRMED. WINDOW VERY HOT. R2 WINDSHIELD HEAT CONTROL UNIT SHOWS SENSOR FAULT. SENSOR TESTED GOOD IAW MM 30-41-21. REPLACED WHCU AS A PRECAUTION. OPS CHECKED GOOD IAW MM 30-41-11. OPS CHECK R2 WINDOW HEAT GOOD IAW MM 30-41-00. REGULATES AROUND 108 DEG F. FAULT REPEATED. SWAPPED TO SECONDARY R2 WINDOW TEMP SENSOR AT WINDOW, IAW MM 30-41-21. OPS CHECK R2 WINDOW HEAT GOOD IAW MM 30-41-00. SYS TEST SAME GOOD REF MM 30-41-11.