What was found
AFT CARGO BAY LT BS 827-947, S25L, FLOOR TRANSITION ANGLE HAS NUMEROUS AREAS OF CORROSION. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMITS, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1. REMOVED, FABRICATED NEW AND INSTALLED NEW TRANSITION PANEL IAW SRM 51-40-02-0G-0, W 3.0", O .040, R .000, L 120.00, D .040.