What was found
DENT FOUND IN FWD CARGO BAY FLOOR PANEL AT APPROXIMATELY FS 500 WITH SMALL CRACK APPROX 1 INCH IN LENGTH. ACFT GROUNDED. FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05-0G-0 AND 53-30-53-01-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT FOUND IN FWD CARGO BAY FLOOR PANEL AT APPROXIMATELY FS 500 WITH SMALL CRACK APPROX 1 INCH IN LENGTH. ACFT GROUNDED. FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05-0G-0 AND 53-30-53-01-1.