What was found
BANK SELECTOR KNOB, MODE CONTROL PANEL 25 & 30 ONLY. ACFT GROUNDED. REPLACED MCP IAW MM 22-11-34, OPS CHECKED NORMAL. ACCOMPLISHED DFCS LRU MCP NR 32 TEST, LAND VERIFY NR 49, & HGS FCC/AT SENSOR TEST, ALL TEST NORMAL IAW MM 22-11-34, 22-11-00, & SMM:34-36-00. ACFT REMAINS CAT IIIA AUTOLAND & HGS QUAL, & STATUS SCREW SHOW SAME.