What was found
AUTOLAND NOT SUCCESSFUL. AT APPROXIMATELY 75 FT, THE ACFT ROLLED TO THE RIGHT. DRIFTING RIGHT, CORRECTED BUT LANDED AWKWARDLY - DRIFTING BACK LEFT SLIGHTLY NOSE HIGH - CRITICAL AREAS PROTECTED. ACFT GROUNDED. NO FAULTS LOGGED IN FFR, DFCS, ACCOMPLISHED LAND VERIFY TEST IAW 22-11-00. HGS LOGGED 'ILS ANOMALY' LAST LEG, ACCOMPLIGH HGS OPS TEST IAW 34-36-00. ALL TESTS PASS, ACFT REMAINS CAT III AUTOLAND/HGS, SCREW REFLECTS SAME.