What was found
AT TOP OF DESCENT, RECEIVED SINGLE FMC OPERATIONS WITH RT VTR AND MAP LIGHT. FOLLOWED QRH, RT FMC FAILURE. ACFT GROUNDED. CYCLED RT FMCS BREAKERS, DUAL OPS RESTORED, RT FMC OPERATIONAL TEST NORMAL REF. AMM 34-61-00-710-801. GROUND VERIFICATION GOOD.