What was found
R2 WINDOW OVERHEAT LIGHT ILLUMINATED DURING TAXI OUT. ACFT GROUNDED. CONTROL UNIT SHOWS SENSOR FAULT. VERIFIED SENSOR IS OPEN WITH METER. SWAPED SENSOR ON WINDOW IAW FIM 30-41, TASK 811. GROUND VERIFICATION CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R2 WINDOW OVERHEAT LIGHT ILLUMINATED DURING TAXI OUT. ACFT GROUNDED. CONTROL UNIT SHOWS SENSOR FAULT. VERIFIED SENSOR IS OPEN WITH METER. SWAPED SENSOR ON WINDOW IAW FIM 30-41, TASK 811. GROUND VERIFICATION CHECKED GOOD.