What was found
L2 DOOR INNER WEB PUNCTURED NEAR UPPER HINGE PRESSURE PANEL. ACFT GROUNDED. REPAIRED L2 DOOR INNER WEB IAW EA: COMPT-52EA-14216, REV-NEW DATED 28JAN2015 AND REO-G18700, REV A DATED 21JAN2015. TITLE "AFT ENTRY, L2 DOOR, INTERNAL UPPER SKIN PUNCTURE REPAIR.", DOT REMOVED.