What was found
START VALVE NR 1 STAYED OPEN AFTER START. ACFT GROUNDED. R & R NR 1 ENG START VALVE IAW AMM 80-11-03. NR 1 ENG START VALVE TESTS GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
START VALVE NR 1 STAYED OPEN AFTER START. ACFT GROUNDED. R & R NR 1 ENG START VALVE IAW AMM 80-11-03. NR 1 ENG START VALVE TESTS GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL.