What was found
WEIGHT & BALANCE NUMBERS FROM ACARS NOT INTERFACING CORRECTLY WITH FMC ON TRIM & POWER SETTINGS. ACFT GROUNDED. VERIFIED FAULT. OPEN 4 C/B'S, 2 FOR RT FMC & 2 FOR ACARS CMU AND CLOSED SAME 4 C/B'S. VERIFIED WEIGHT & BALANCE NUMBERS'S & TRIM & POWER SETTING ARE NOW SHOWING. ACCOMPLISHED ACARS OPS TEST, TEST PASS REF MM 23-27-00-740-8166-010 & ACCOMPLISHED FMC OPS TEST, TEST PASS REF 34-61-00-710-801.