What was found
L2 DOOR BINDS ON OPENING. ACFT GROUNDED. FOUND SNUBBER CAUSING BINDING & GUIDE ARM OUT OF RIG. REMOVED L-2 DOOR SNUBBER & INSTALLED SERVICEABLE SNUBBER. TESTED GOOD REF AMM 52-13-51-000-801 & 52-13-51-400-801 STEP3, B, C, D, E & F & STEP F. ADJUSTED L-2 DOOR GUIDE ARM REF AMM 52-13-00-820-801, STEPS 2. I. L, A, B 1 THRU 12. ACCOMPLISHED DOOR SYS TEST. TESTED GOOD REF AMM 52-13-00-700-805.