What was found
NR 2 ENGINE START, FAILED OPEN AFTER START. ACFT GROUNDED. OPERATED START VALVE MANUALLY TO CLOSED & OPENED POSITION. START VALVE AUTOMATICALLY CLOSED. PERFORMED OPS TEST OF START VALVE DURING START & RUN. START VALVE OPS TEST & LIGHT INDICATION TEST GOOD. IAW AMM TASK 80-11-03-400-801-F00 & TASK 71-00-00-800-811-F00.