What was found
PILOT REPORT APU DON'T START AND HAVE FAULT LIGHT. ACFT GROUNDED. TECH SERVICES REQUESTS FOLLOW UP. PERFORMED FIM 49-90, TASK 802 AS REQUESTED FROM BEGINNING THRU STEP F.4. APU BITE SHOWED NO CURRENT FAULTS BUT FOUND MSG 49-61224 INLET TEMP SENSOR SHOWS OUT OF RNG HIGH AFTER SHUTDOWN. R & R INLET TEMP SENSOR IAW STEP F. 4. APU START & OPS NORMAL IAW AMM 49-11-00 AND APU BITE OPS NORMAL IAW FIM 49-60 TASK 801, NO FAULTS AFTER SHUTDOWN. GROUND VERIFICATION SUCCESSFUL.