Service difficulty report · Sensor · Boeing 737890

Difficulty date
May 23, 2015
Submitted
May 26, 2015
Operation
Air carrier
Aircraft
N537AS
Make and model
Boeing 737890
Aircraft serial
35204
Aircraft time
13,215 hours, 3,940 cycles
Part
Sensor
Part number
1019755
Condition
Failed
Location
Window Heat
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT FWD WINDOW OVERHEAT LIGHT ILLUMINATED WHEN WINDOW HEAT SWITCH TURNED ON. ACFT GROUNDED. PERFORMED WHCU BITE PROCEDURE, REF FIM 30-41, TASK 801. RT FWD CONTROLLER FAULTED P5-9 / CON POWER. PERFORMED FIM 30-41 TASK 813 WITH NO HELP. SWAPPED FWD RT CONTROLLER WITH SIDE LT CONTROLLER FAULT DID NOT FOLLOW THEN SWAPPED CONTROLLERS BACK TO ORIGINAL POSITIONS. DURING T/S PLACED WINDSHIELD SENSOR TO SPARE POSITION REF AMM 30-411-00-420-801. CYCLED SHIPS POWER FAULT CLEARED. PERFORMED BITE PROCEDURES FOR WHCU. OPERATION OF WINDOW HEAT NORMAL GROUND VERIFICATION OF SYS GOOD. ACFT OK FOR SERVICE.