What was found
NR 1 SOURCE OFF LIGHT ILLUMINATED. NO VOLTS/ FREQUENCY IN CRUISE AT 36,000 FT. ACFT GROUNDED. ACCOMPLISHED GCU BITE TEST NR 1 IAW FIM 24-21, TASK 801, AND RESET. C/W FIM 24-21, TASK 823 SOURCE OFF LIGHT ILLUMINATED AFTER NR 1 ENGINE GROUND RUN, GROUND VERIFICATION SUCCESSFUL. NR 1 SOURCE OFF LIGHT REMAINS EXTINGUISHED, ALL OTHER INDICATIONS NORMAL.