What was found
DURING MASTER CAUTION RECALL, LEFT PACK LIGHT ILLUMINATED. LIGHT EXTINGUISHED WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. NR 1 ZONE TEMP CONTROLLER WITH TEMP CONTROL VALVE FAULT. CLEARED FAULT AND BITE TESTS NORMAL IAW FIM 21-61, TASK 801. ETOPS SIGNIFICANT SYS, GROUND VERIFICATION SUCCESSFUL.