Service difficulty report · Valve · Boeing 737990ER

Difficulty date
June 30, 2015
Submitted
July 2, 2015
Operation
Air carrier
Aircraft
N459AS
Make and model
Boeing 737990ER
Aircraft serial
36352
Aircraft time
5,101 hours, 1,666 cycles
Part
Valve
Part number
3989083
Part serial
1480
Condition
Failed
Location
Lt A/C Pack
Part time
72,151 hours, 39,546 cycles
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

JUST AFTER T/O, COCKPIT TEMP VERY WARM, W/CONTOL CABIN & FWD IN FULL COLD WERE STILL GETTING 62 DEG C. ON CONT CAB SUPPLY DUCT. CALLED MX CONTROL, ADVISED TO TURN OFF TRIM AIR, PUT CONTROL CABIN & FWD TO MANUAL. FULL COLD FOR 7 MIN = NO CHANGES, 61 DEGREES C, SUPPLY DUCT/LT PACK = 51 DEGREES C. RT=8 DEG C. NORMAL TEMPS IN BACK. B, AFTER 7 MIN, KEPT TRIM AIR OFF & TRIED ALL 3 TEMPS IN AUTO/12'OCLOCK FOR 6 MIN = NO CHANGES LT PACK 51 DEG C, RT 8 DEGREES C. AFTER 1+343 MIN IN FLT, WE TURNED LT PACK, 46 DEG C. OFF W/ALL TEMPS AT 12 O`CLOCK & ISOLATION VALVE IN CLOSED. ALL TEMPS RETURNED TO NORMAL, CABIN ALT STAYED AT 7500 MSL, +35,000MSL CONTINUED TO SEA. ACFT GROUNDED. LT PACK TEMP CONTINUED FAULTS TCV DURING BITE CK IAW FIM 21-62, TASK 801. REPLACED LT TEMP CONTROL VALVE REF AMM 21-51-10-000-801 AND 21-51-10-400-801. OPS CHECK NORMAL.